The Quanta MDK II combines Nd: YAG Q-Switched (1064nm & 532nm) with a Long pulsed Alexandrite 755 nm.

The MDK Multi-Application Platform is unique in its power and versatility. The wavelengths are pulsed individually and cannot be fired simultaneously. The MDK can include most of the following features, depending on the model chosen:

Download our White Paper from Stephen W. Eubanks, M.D. on the use of the MDK Platform for leg vein treatment.

Twain IPL is an optional pulsed light upgrade that allows you to expand your treatment options and profitability with your Quanta Light Series, MDK Series or Q-Plus Series device.

Available with up to six interchangeable waveguides which are simple to connect and easy to operate, adding either single-pulse or burst-mode IPL treatment options to the above listed Quanta lasers.Twain IPL Handpiece

Standard Interchangeable Waveguides

  • 625 – 1200 nm for hair removal
  • 570 – 1200 nm for facial vascular and benign pigmented lesions
  • 550 – 1200 nm for facial vascular and benign pigmented lesions
  • 400 – 1200 nm for inflammatory acne treatments

Optional Interchangeable Waveguides

  • 650 – 1200 nm for hair removal
  • 590 – 1200 nm for hair removal
  • Tattoo Removal

    Sleeve Tattoo Removal Before and After
  • Tattoo Removal

    Before and After Laser Tattoo Removal
  • Tattoo Removal

    Laser Tattoo Removal on Shoulder Before and After
  • Tattoo Removal

    Laser Tattoo Removal on Elbow Before and After
  • Permanent Makeup Removal

  • Melasma

  • Pigmented Lesion

  • Pigmented Lesion

  • Pigmented Lesion

  • Active Acne

    Performed with optional Twain IPL

  • Vascular Lesion

    Performed with optional Twain IPL

  • Pigmented Lesion

    Performed with optional Twain IPL

  • After buying two Q-Plus C systems, we decided our third Quanta system would be the MDK II and it’s been a perfect fit for our business. Now that we can offer tattoo removal and hair removal, we’re able to differentiate ourselves from our competitors that only offer one or the other. Like all Quanta devices, the MDK system is sturdy & strong and because the platform is aligned with the Q-Plus C, it has been very easy for our technicians to adapt to the new system.

    - Aleks Nedich, Fade Away Laser Tattoo Removal

Nd: YAG 1064 Q-Switched and 532 Q-Switched The MDK Multi-Applications Platform is intended for treatment of vascular lesions, pigmented lesions, and for hair, tattoo removal and the incision, excision, ablation, vaporaization of soft tissue. General dermatology: (ablation, vaporization, incision, excision, coagulation of soft tissue) indicated for treatment such as, but not limited to treatment of: Tattoo removal- 1064nm: suggested for dark blue and black ink. 532nm: suggested for red, orange, yellow and purple ink. Pigmented lesion removal (benign)- cafe au lait spot. Ephalides, solar lentigo (lentigines). Becker Nevus. Ota Nevus. Nevus spilus.

Alexandrite 755nm Intended for the coagulation and hemostasis of vascular lesions and the removal and permanent reduction of unwanted hair in Fitzpatrick skin types I-VI, including suntanned skin types. Also indicated for pigmented lesions and wrinkles. Permanent hair reduction is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime. Dermatology/ Plastic Surgery: For photocoagulation and hemostasis of vascular and cutaneous lesions in dermatology including but not limited to, the following general categories: vascular lesions (angiomas, hemangiomas (port wine), telangiectasia (facial or extremities telangiectasias, venous anomalies, leg veins) benign pigmented lesions (nevi, lentigines, chloasma, cafe au lait, tattoos (red and green ink), verrucae, skin tags, keratoses, plaques, cutaneous lesion treatment (hemostasis, color lightening, blanching, flattening, reduction in lesion size.

Integrated Skin Cooler The intended use of the integrated skin cooling system in the MDK Multi-Applications Platform hand-piece is to provide cooling of the skin prior to laser treatment, for the reduction of pain during laser treatment, to allow for the use of higher fluencies for laser treatments such as hair removal and vascular lesion, and to reduce the potential side effects of laser treatments. Any other different use is considered incorrect.


Optional Upgrades

IPL 590-1200nm; 625-1200nm; 650-1200nm Indicated for permanent hair removal. Permanent hair reduction is defined as the long-term, stable reduction in the number of hairs regrowing when measured at 6, 9, and 12 months after the completion of a treatment regime.

IPL 550–1200nm; 570-1200nm Indicated for the photocoagulation of dermatological vascular lesion (i.e. face telangiectasia), photothermolysis of blood vessels (treatment of facial and leg veins), and the treatment of benign pigmented lesions.

IPL 400-1200nm Indicated for inflammatory acne (acne vulgaris).

Nd:YAG 1320 Indicated for use in general surgery and dermatology for the incision, excision, ablation, vaporization, coagulation and hemostasis of soft tissue. It is also indicated for the treatment of periorbital and perioral wrinkles, fine lines and wrinkles, and the treatment of back acne and atrophic acne scars.

 

Source Wavelength max power/energy Pulsewidth Rep Rate Spot Size Fluence Burst Mode Cooling Electrical Dimension
Nd:YAG 1064 qs 1J 6ns 1, 2, 5, 10Hz 2,3,4,6,8,9 mm
30 J/cm2 at 2mm
14 J/cm2 at 3mm
7 J/cm2 at 4mm
3.5 J/cm2 at 6mm
1.8 J/cm2 at 8mm
1.4 J/cm2 at 9 mm
na integrated skin cooler 230 VAC; 50/60 Hz; 16A 480(W) x 900(D) x 930(H) mm
Nd:YAG 532 qs 0.5J 6ns 1, 2, 5, 10Hz 2,3,4,6,8,9 mm
15 J/cm2 at 2mm
7 J/cm2 at 3mm
4 J/cm2 at 4mm
1.7 J/cm2 at 6mm
1 J/cm2 at 8mm
0.8 J/cm2 at 9mm
na integrated skin cooler 230 VAC; 50/60 Hz; 16A 480(W) x 900(D) x 930(H) mm
Alexandrite 755 lp 38J up to 100ms Up to 2.0 Hz 6-20 mm
123 J/cm2 at 6mm
>100 J/cm2 at 8mm
75 J/cm2 at 10mm
50 J/cm2 at 12mm
35 J/cm2 at 14mm
30 J/cm2 at 16mm
23 J/cm2 at 18mm
20 J/cm2 at 20mm
na integrated skin cooler 230 VAC; 50/60 Hz; 16A 480(W) x 900(D) x 930(H) mm
IPL
590-1200nm; 625-1200nm; 650-1200nm
550-1200nm;570-1200nm
400-1200nm
N/A 3 ms and 40 ms up to 0,5 48mm x13 mm
25mm x13 mm
Large light guide: 35 J/cm2
Small light guide: 50 J/cm2
2-5 pulses 230 VAC; 50/60 Hz; 16A 480(W) x 900(D) x 930(H) mm
.What can we help you with?  Quanta Aesthetic Lasers takes a consultative approach to sales and can help guide and educate you throughout your research and purchase processes.  We offer a full portfolio of high-end, European aesthetic devices, and our Sales Team is well-trained in both our technology and other lasers you may be looking at.  We will take the time to walk you through the benefits of your many options.
.