• OptiBeam II® Technology

    The OptiBeam™ II technology is extremely important for any application where Picosecond and Q-switched laser is involved. The laser beam profile must be as homogeneous as possible, otherwise longer healing time and side effects can occur. The extremely high laser peak power of these devices has to treat the skin without any “hot points” in the spot size. The OptiBeam™ handpiece assures a perfect flat top beam profile due to its advanced optical technology, distributing the laser power homogeneously all over the spot size.

  • FAST!

    2 minute warm up time

    ■ Optimized software and hardware allows for virtually no start up time.
    ■ This allows you to turn the system off in between patients, keeping the room temperature comfortable and increasing the life of the laser.

  • 10.4" Gorilla Glass Touchscreen

    New display utilizing the same technology used in today's smartphones

    ■ Touch sensitivity has been increased and It can now be used while wearing treatment gloves.
    ■ Super Durable: can be cleaned normally without to risk of damaging the screen.

  • Main Operating Screen

    New easy to use touchscreen interface.

    ■ Manage all of your treatment and system settings from one screen
    ■ Store your commonly used treatment settings in the new User Treatments Database

Additional Features:

  • Cost effective ownership with no consumable costs: no sprays, no tips, no cards, no hassles!
  • Optional Twain IPL accessory can be added to expand your treatment offerings even further
  • 360° rotating caster wheels with 3 operating positions that allow the system to be maneuvered in small spaces
  • Tattoo Removal

    Results after only 1 treatment

  • Tattoo Removal

    Results after only 1 treatment

  • Tattoo Removal

    Results after 4 treatments

  • Benign Pigmentation Removal

  • Benign Pigmentation Removal

Laser Nd:YAG 1064 nm Nd:YAG 532 nm Ruby 694 nm
Prima Pico Plus
Prima Pico

* These wavelengths are not pulsed simultaneously.

Twain IPL System can be added to any of the above configurations
See More Info

510(k) FDA Premarket Notification Number: K160368

Twain IPL

Optional pulsed light upgrade that allows you to expand your treatment options and profitability with your Quanta Primo Pico Series, EVO Light Series, EVO MDK Series or EVO Q-Plus Series device.

Available with up to six waveguides which are simple to connect and easy to operate, adding either single-pulse or burst-mode IPL treatment options to the above listed Quanta lasers.Twain IPL Handpiece

Optional Interchangeable Waveguides

  • 650 – 1200 nm for hair removal
  • 625 – 1200 nm for hair removal
  • 590 – 1200 nm for hair removal
  • 570 – 1200 nm for facial vascular and benign pigmented lesions
  • 550 – 1200 nm for facial vascular and benign pigmented lesions
  • 400 – 1200 nm for inflammatory acne treatments

Zimmer Cryo 6

The Zimmer Cryo 6 is an integrated cooling system that maximizes patient comfort while minimizing side effects. It won the Editor’s Choice Award for Best Stand Alone Epidermal Cooling Device from Aesthetic Trends and Technologies, and continues to be a favorite of clinics throughout the world.

Zimmer Cryo 6

The EVO Platform is intended for use in aesthetic, cosmetic and surgical applications requiring incision, excision, ablation, vaporization and coagulation of body soft tissues in the medical specialties of dermatology, general, plastic and oral surgery as follows:

Source selection and wavelength Indications for Use
532 nm (picosecond mode) Indicated for the removal of tattoos for Fitzpatrick skin types I-III to treat the following tattoo colors: red, yellow and orange.

Indicated for benign pigmented lesions removal for Fitzpatrick skin types I-IV.

1064 nm (picosecond mode) Indicated for the removal of tattoos for all skin types (Fitzpatrick skin types I-VI) to treat the following tattoo colors: black, brown, green, blue and purple.

Indicated for benign pigmented lesions removal for Fitzpatrick skin types I-IV.

694 nm (Q-Switched, nanosecond mode) Tattoo Removal: suggested for blue, sky blue, black, green and violet ink

Removal of benign pigmented lesions including:
– Café au lait spot
– Ephelides
– Solar lentigo (lentigines)
– Becker Nevus
– Ota and Ito Nevus
– Nevus spilus
– Mongolian spot

1064 & 532 nm (Q-Switched, nanosecond mode) The EVO Platform is intended for treatment of vascular lesions, pigmented lesions, and for hair, tattoo removal and the incision, excision, ablation, vaporization of soft tissue for General dermatology such as, but not limited to treatment of:
532 nm (Q-Switched, nanosecond mode) Removal of light ink (red, sky blue, green, tan, purple, and orange) tattoos.

Treatment of vascular lesions including, but not limited to: port wine birthmarks, telangiectasias, spider angioma, Cherry angioma, Spider nevi.

Treatment of benign pigmented lesions including, but not limited to:

cafe-au-lait birthmarks, Ephalides, solar lentigines, senile lentigines, Becker’s nevi, freckles, common nevi, nevus spilus, Ota Nevus.

Treatment of seborrheic keratosis.

Treatment of post inflammatory hyperpigmentation.

Skin resurfacing procedures for the treatment of acne scars and wrinkles.

1064 nm (Q-Switched, nanosecond mode) Removal of dark ink (black, blue and brown) tattoos , Removal of benign pigmented lesions including:

nevus of Ota, Café au lait spot , Ephelides, solar lentigo (lentigines), Becker Nevus, Nevus spilus, Treatment of common nevi, Removal or lightening of unwanted hair, Skin resurfacing procedures for the treatment of acne scars and wrinkles.

1064 nm (non Q-Switched – free running mode or PT mode) Removal of unwanted hair, for stable long term or permanent hair reduction and for treatment of PFB. The laser is indicated for all skin types, Fitzpatrick I-VI, including tanned skin. Photocoagulation and hemostasis of pigmented and vascular lesions, such as, but not limited to port wine stains, hemangiomas, warts, telangiectasia, rosacea, venus lake, leg veins and spider veins. Coagulation and hemostasis of soft tissue. Treatment of wrinkles. Treatment of mild to moderate inflammatory acne vulgaris.
694 nm (non Q-Switched, free running mode) Intended to remove benign dermal and epidermal pigmented lesions, and, to effect hair removal of patients with skin types I-IV through selective targeting of melanin in hair follicles in dermatology and plastic surgery.

510(k) FDA Premarket Notification Number: K152012

Nd:YAG
(Picosecond)
Nd:YAG
(Picosecond)
Ruby
(Q-Switched)
Nd:YAG
(Q-Switched)
Nd:YAG
(Q-Switched)
Nd:YAG
(Opti-Pulse™)
Nd:YAG
(Opti-Pulse™)
Nd:YAG
(Free Running)
Wavelength 1064 nm 532 nm 694 nm 1064 nm 532 nm 1064 nm 532 nm 1064 nm
Pulse width 450 ps 400 ps 30 ns 6 ns 6 ns 12 ns 12 ns 250 µs
Max Energy 400 mJ 200 mJ  1200 mJ 800 mJ 400 mJ  1200 mJ 450 mJ 2000 mJ
Peak Power 0.90 Gigawatts 0.50 Gigawatts 40 Megawatts 133 Megawatts 67 Megawatts 100 Megawatts 37 Megawatts 8 Watts
Beam Delivery Articulated Arm
Repetition rate up to 10 Hz up to 10 Hz up to 3 Hz up to 10 Hz up to 10 Hz up to 10 Hz up to 10 Hz up to 10 Hz
Spot sizes 5×5, 4×4, 3×3 mm
9×9, 2×2 mm(optional)
Cooling Options Optional stand-alone Zimmer Cryo 6 (purchased separately)
Electrical requirements 200-240 V; 3.7 kVA; 50-60 Hz
Comes standard with NEMA L630 plug.
Dimensions and Weight 21″(W)x41″(D)x42″(H)  |  330lbs.

The wavelengths are pulsed individually and cannot be fired simultaneously.

510(k) FDA Premarket Notification Number: K160368

 

To learn more about adding a Prima Pico to your business, please contact us using your preferred method of communication.

 

CALL  844-694-1064

 

TEXT “QUANTA” to 41411

 

EMAIL BY SUBMITTING THE FORM