THE SCIENCE THAT ENABLES
THE DEVICE TO WORK LIKE MAGIC

 

POWER

Large spot sizes + High Fluence = Greater depth of penetration.

 

PULSE WIDTH

Effectively shatter ink and pigment particles with ease.

 

THREE WAVELENGTHS

Selectively target all treatable ink colors.

 

OPTIBEAM II BEAM PROFILE

Homogeneous energy delivery for better patient outcomes.

 

EMISSION MODES

(QS) Q-Switched | (OP) Opti-Pulse | (PT) Photo-Thermal.

 

 

  • FAST!

    ■ Optimized software and hardware allows for virtually instant-on ready time.
    ■ Turn the system off in between patients: keep the room temperature comfortable and increase the life of the laser.
    ■ 10Hz Nd:YAG & 3Hz Ruby for ultra fast treatment times: see more patients per hour than ever before.

  • OptiBeam II® Technology

    The OptiBeam™ II technology is extremely important for any application where Picosecond and Q-switched laser is involved. The laser beam profile must be as homogeneous as possible, otherwise longer healing time and side effects can occur. The extremely high laser peak power of these devices has to treat the skin without any “hot points” in the spot size. The OptiBeam™ II handpiece assures a perfect flat top beam profile due to its advanced optical technology, distributing the laser power homogeneously all over the spot size.

  • 10.4" Gorilla Glass Touchscreen

    New display utilizing the same technology used in today's smartphones

    ■ Touch sensitivity has been increased and It can now be used while wearing treatment gloves.
    ■ Super Durable: can be cleaned normally without to risk of damaging the screen.

ADDITIONAL FEATURES

 

  • Cost effective ownership with no consumable costs: no sprays, no tips, no cards, no hassles!
  • Chilled IPL and 2940 Er:YAG handpieces can be added to expand your treatment offerings even further by offering hair removal, vascular lesions, pigmented lesions, acne, wrinkles, skin resurfacing, and scar revision.
  • 360° rotating caster wheels with 3 operating positions that allow the system to be maneuvered in small spaces
  • Three possible system configurations with up to 3 laser sources + 6 filter IPL

 

THE EVO Q-PLUS™ SERIES UTILIZES THE SAME HARDWARE AND SOFTWARE PLATFORM WITH 1, 2 or 3 LASER SOURCES, FROM THE EVO Q-PLUS C WHICH INCLUDES 3 LASER SOURCES TO A STAND-ALONE RUBY LASER (EVO Q-PLUS R):

Laser Nd:YAG 1064 nm
(Q-Switched)
Nd:YAG 532 nm
(Q-Switched)
Ruby 694 nm
(Q-Switched)
EVO Q-Plus C
EVO Q-Plus A  ■
EVO Q-Plus R  ■

* These wavelengths are not pulsed simultaneously.

Twain IPL System can be added to any of the above configurations
See More Info

510(k) FDA Premarket Notification Number: K152012

  • Tattoo Removal

    Laser Tattoo Removal Before and After

    Photo Courtesy Of: Second Skin Tattoo Removal

  • Tattoo Removal

    Photo Courtesy Of: Dissapearing Inc

  • Tattoo Removal

  • Tattoo Removal

    Before and After Laser Tattoo Removal

    Photo Courtesy of: Dr. Zerbinati

  • Tattoo Removal

    Sleeve Tattoo Removal Before and After

    Photo Courtesy of: Dr. Zerbinati

  • Tattoo Removal

    Laser Tattoo Removal on Forearm Before and After
  • Tattoo Removal

    Photo Courtesy Of: Dissapearing Inc

  • Tattoo Removal

    Laser Tattoo Removal on Elbow Before and After

    Photo Courtesy of: Dr. Zerbinati

  • Tattoo Removal

    Laser Tattoo Removal on Ankle Before and After
  • Tattoo Removal

    Photo Courtesy Of: Dissapearing Inc

  • Tattoo Removal

    Laser Tattoo Removal on Shoulder Before and After
  • Permanent Makeup Removal

  • Permanent Makeup Removal

  • Pigmented Lesions

  • Pigmented Lesions

  • Pigmented Lesions

    Photo Courtesy of: Dr. Catenacci

  • Melasma

 

 

 

 

Zimmer Cryo 6

The Zimmer Cryo 6 is an integrated cooling system that maximizes patient comfort while minimizing side effects. It won the Editor’s Choice Award for Best Stand Alone Epidermal Cooling Device from Aesthetic Trends and Technologies, and continues to be a favorite of clinics throughout the world.

Zimmer Cryo 6

Indications for Use

The EVO Platform is intended for use in aesthetic, cosmetic and surgical applications requiring incision, excision, ablation, vaporization and coagulation of body soft tissues in the medical specialties of dermatology, general, plastic and oral surgery as follows.

Source selection and wavelength Indications for Use
1064 nm (Q-Switched, nanosecond mode) Removal of dark ink (black, blue and brown) tattoos

Removal of benign pigmented lesions including:
– Nevus of Ota
– Café au lait spot
– Ephelides
– Solar lentigo (lentigines)
– Becker Nevus
– Nevus spilus
– Treatment of common nevi

Removal or lightening of unwanted hair

Skin resurfacing procedures for the treatment of acne scars and wrinkles

532 nm (Q-Switched, nanosecond mode) Removal of light ink (red, sky blue, green, tan, purple, and orange) tattoos

Treatment of vascular lesions including, but not limited to:
– Port wine birthmarks
– Telangiectasias
– Spider angioma
– Cherry angioma
– Spider nevi

Treatment of benign pigmented lesions including, but not limited to:
– Cafe-au-lait birthmarks
– Ephelides
– Solar lentigines
– Senile lentigines
– Becker’s nevi
– Freckles
– Common nevi
– Nevus spilus
– Ota Nevus

Treatment of seborrheic keratosis

Treatment of post inflammatory hyperpigmentation

Skin resurfacing procedures for the treatment of acne scars and wrinkles.

694 nm (Q-Switched, nanosecond mode) Tattoo Removal: suggested for blue, sky blue, black, green and violet ink

Removal of benign pigmented lesions including:
– Café au lait spot
– Ephelides
– Solar lentigo (lentigines)
– Becker Nevus
– Ota and Ito Nevus
– Nevus spilus
– Mongolian spot

1064 nm (non Q-Switched, free running mode) Removal of unwanted hair, for stable long term or permanent hair reduction and for treatment of PFB. The laser is indicated for all skin types, Fitzpatrick I-VI, including tanned skin.

Photocoagulation and hemostasis of pigmented and vascular lesions, such as, but not limited to port wine stains, hemaongiomae, warts, telangiectasiae, rosacea, venus lake, leg veins and spider veins.

Coagulation and hemostasis of soft tissue.

Treatment of wrinkles.

Treatment of mild to moderate inflammatory acne vulgaris.

694 nm (non Q-Switched, free running mode) Intended to remove benign dermal and epidermal pigmented lesions, and, to effect hair removal of patients with skin types I-IV through selective targeting of melanin in hair follicles in dermatology and plastic surgery.

 

Optional Accessories Indications for Use
IPL 650-1200 nm
IPL 625-1200 nm
IPL 590-1200 nm
Indicated for permanent hair removal.
IPL 570-1200 nm
IPL 550-1200 nm
Indicated for photocoagulation of dermatological vascular lesion (i.e. face telangiectasia), photothermolysis of blood
vessels (treatment of facial and leg veins), and treatment of benign pigmented lesions.
IPL 400-1200 nm Indicated for inflammatory acne (acne vulgaris).
Er:YAG 2940 nm (Pulsed) Indicated for use in soft tissue (skin and cutaneous tissue) such as,
but not limited to: Dermatology and plastic Surgery: Skin resurfacing; Treatment of wrinkles; Epidermal nevi;
Telangiectasia; Spider veins; Actinic chelitis; Keloids; Verrucae; Skin tags; Anal tags; Keratoses; Scar revision (including acne scars).
With microbeam end piece it is indicated for Skin resurfacing.

 

510(k) FDA Premarket Notification Number: K160368 and K173002

Quanta’s world-renowned Q-Switched technology, with up to three (3) powerful wavelengths, and (3) three versatile pulsing modes:

Laser Nd:YAG Nd:YAG Ruby
Wavelength (nm) 1064 532 694
Emission Modes QS, OP, PT QS, OP QS, PT
Repetition rate (Hz) up to 10 up to 10 up to 3
Spot sizes (mm) 5×5, 4×4, 3×3
2×2 (optional)
Max Energy (mJ) 2000 in PT mode
1500 in OP mode
1000 in QS mode
600 in OP mode
500 in QS mode
2000 in PT mode
1200 in QS mode
Electrical requirements 200-240 V; 3.7 kVA; 50-60 Hz
Comes standard with NEMA L630 plug.
Dimensions and Weight 21″(W)x41″(D)x42″(H)  |  330lbs.

510(k) FDA Premarket Notification Number: K152012

Emission Modes:

  • Q-Switched Mode (QS):
    • Nd:YAG 1064nm: delivered at a pulse width of 6 ns.
    • Nd:YAG 532nm: delivered at a pulse width of 6 ns.
    • Ruby 694nm: delivered at a pulse width of 30 ns.
  • Opti-Pulse Mode (OP):
    • Nd:YAG 1064nm: delivered at a pulse width of 12 ns.
    • Nd:YAG 532nm: delivered at a pulse width of 12 ns.
  • Photo-Thermal Mode (PT):
    • Nd:YAG 1064nm: delivered at a pulse width of 250 µs
    • Ruby 694nm: delivered at a pulse width of 2 ms.

Best-in-class Max Energy:

  • Q-Switched Mode:
    • Nd:YAG 1064nm: up to 1000 mJ per pulse
    • Nd:YAG 532nm: up to 500 mJ per pulse
    • Ruby 694nm: up to 1200 mJ per pulse
  • Opti-Pulse Mode:
    • Nd:YAG 1064nm: up to 1500 mJ per pulse
    • Nd:YAG 532nm: up to 600 mJ per pulse
  • Photo-Thermal Mode:
    • Nd:YAG 1064nm: up to 2000 mJ per pulse
    • Ruby 694nm: up to 2000 mJ per pulse

What can we help you with?  Quanta Aesthetic Lasers takes a consultative approach to sales and can help guide and educate you throughout your research and purchase processes.  We offer a full portfolio of high-end, European aesthetic devices, and our Sales Team is well-trained in both our technology and other lasers you may be looking at.  We will take the time to walk you through the benefits of your many options.

The Quanta team is available to you by phone, email, or through your submission of this Contact form.
Contact Us page group photo