• OptiBeam™ II Technology

    The OptiBeam™ II technology is extremely important for any application where Picosecond and Q-switched laser is involved. The laser beam profile must be as homogeneous as possible, otherwise longer healing time and side effects can occur. The extremely high laser peak power of these devices has to treat the skin without any “hot points” in the spot size. The OptiBeam™ II handpiece assures a perfect flat top beam profile due to its advanced optical technology, distributing the laser power homogeneously all over the spot size.

  • FAST! Ready Time

    ■ Optimized software and hardware allows for virtually no start up time.
    ■ This allows you to turn the system off in between patients, keeping the room temperature comfortable and increasing the life of the laser.
    ■ 10Hz Nd:YAG for ultra fast treatment times: see more patients per hour than ever before.

  • 10.4" Gorilla Glass Touchscreen

    New display utilizing the same technology used in today's smartphones

    ■ Touch sensitivity has been increased and It can now be used while wearing treatment gloves.
    ■ Super Durable: can be cleaned normally without to risk of damaging the screen.

Additional Features:

  • Cost effective ownership with no consumable costs: no sprays, no tips, no cards, no hassles!
  • Optional Twain IPL can be added to expand your treatment offerings even further
  • 360° rotating caster wheels with 3 operating positions that allow the system to be maneuvered in small spaces
  • Three possible system configurations with up to 4 laser sources + 6 filter IPL

 

Clinical Whitepapers

whitepaper-img

whitepaper-img-1

THE EVO MDK™ SERIES combines the power and effectiveness of our Q-Switched EVO Q-Plus™ Series with our Pulsed EVO Light™ Series devices, into one Premium Platform System:

Laser Nd:YAG 1064 nm
(Q-Switched)
Nd:YAG 532 nm
(Q-Switched)
Nd:YAG 1064 nm
(Pulsed)
Nd:YAG 532 nm
(Pulsed)
Alexandrite 755 nm
(Pulsed)
Nd:YAG 1320 nm
(Pulsed)*
EVO MDK I ■*
EVO MDK II
EVO MDK III  ■  ■

Twain IPL System can be added to any of the above configurations
See More Info

* Nd:YAG 1320nm is an optional upgrade and not included with the standard configuration.

510(k) FDA Premarket Notification Number: K152012

  • Tattoo Removal

    Laser Tattoo Removal on Shoulder Before and After
  • Tattoo Removal

    Laser Tattoo Removal on Elbow Before and After
  • Tattoo Removal

    Laser Tattoo Removal on Ankle Before and After
  • Pigmented Lesion

  • Pigmented Lesion

  • Pigmented Lesion

  • Melasma

  • Hair Removal

    Mens Chest Laser Hair Removal Before and after
  • Vascular Lesion

  • Vascular Lesion

  • Leg Veins

  • Fine Lines and Wrinkles

  • Active Acne

    Performed with optional Twain IPL

  • Vascular Lesion

    Performed with optional Twain IPL

Twain IPL

Optional pulsed light upgrade that allows you to expand your treatment options and profitability with your Quanta Primo Pico SeriesEVO Light Series, EVO MDK Series or EVO Q-Plus Series device.

Available with up to six interchangeable waveguides which are simple to connect and easy to operate, adding either single-pulse or burst-mode IPL treatment options to the above listed Quanta lasers.

Twain IPL Handpiece

Standard Interchangeable Waveguides

  • 625 – 1200 nm for hair removal
  • 570 – 1200 nm for facial vascular and benign pigmented lesions
  • 550 – 1200 nm for facial vascular and benign pigmented lesions
  • 400 – 1200 nm for inflammatory acne treatments

Optional Interchangeable Waveguides

  • 650 – 1200 nm for hair removal
  • 590 – 1200 nm for hair removal

Zimmer Cryo 6

The Zimmer Cryo 6 is an integrated cooling system that maximizes patient comfort while minimizing side effects. It won the Editor’s Choice Award for Best Stand Alone Epidermal Cooling Device from Aesthetic Trends and Technologies, and continues to be a favorite of clinics throughout the world.

Zimmer Cryo 6

The EVO Platform is intended for use in aesthetic, cosmetic and surgical applications requiring incision, excision, ablation, vaporization and coagulation of body soft tissues in the medical specialties of dermatology, general, plastic and oral surgery as follows.

Source selection and wavelength Indications for Use
1064 nm (Q-Switched, nanosecond mode) Removal of dark ink (black, blue and brown) tattoos

Removal of benign pigmented lesions including;
– Nevus of Ota
– Café au lait spot
– Ephalides, solar lentigo (lentigines)
– Becker Nevus
– Nevus spilus

Treatment of common nevi Removal or lightening of unwanted hair

Skin resurfacing procedures for the treatment of acne scars and wrinkles

532 nm (Q-Switched, nanosecond mode) Removal of light ink (red, sky blue, green, tan, purple, and orange) tattoos

Treatment of vascular lesions including, but not limited to:
– Port wine birthmarks
– Telangiectasias
– Spider angioma
– Cherry angioma
– Spider nevi

Treatment of benign pigmented lesions including, but not limited to:
– Cafe-au-Iait birthmarks
– Ephalides, solar lentigines
– Senile lentigines
– Becker’s nevi
– Freckles
– Common nevi
– Nevus spilus
– Ota Nevus

Treatment of seborrheic keratosis

Treatment of post inflammatory hyperpigmentation

Skin resurfacing procedures for the treatment of acne scars and wrinkles.

1064 nm (non Q-Switched, free running mode) Removal of unwanted hair, for stable long term or permanent hair reduction and for treatment of pseudofolliculitis barbae (PFB)

Photocoagulation and hemostasis of pigmented and vascular lesions, such as, but not limited to:
– Port wine stains
– Hemaongiomae
– Warts
– Telangiectasia
– Rosacea
– Venus lake
– Leg veins and spider veins

Coagulation and hemostasis of soft tissue

Treatment of wrinkles

Treatment of mild to moderate inflammatory acne vulgaris.

The laser is indicated for all skin types, Fitzpatrick I-VI, including tanned skin.

1064 nm (Pulsed) Intended for the coagulation and hemostasis of benign vascular lesions such as, but not limited to:
– Port wine stains
– Hemangiomas
– Warts
– Telangiectasia
– Rosacea
– Venus lake
– Leg veins
– Spider veins
– Poikiloderma of civatteTreatment of benign cutaneous lesions such as:
– Warts
– Scars
– Striae
– PsoriasisThe laser is also intended for the treatment of benign pigmented lesions such as, but not limited to:
– Lentigos (age spots)
– Solar lentigos (sun spots)
– Cafe au lait macules
– Seborrheic keratoses
– Nevi
– Chloasma
– Verrucae
– Skin tags
– Keratosis and plaquesThe laser is also indicated for the treatment of wrinkles such as, but not limited to:
– Periocular and perioral wrinkles
– Facial wrinkles

Additionally, the laser is indicated for the treatment of pseudofolliculitis barbae (PFB) and for stable long-term, or permanent hair reduction. Permanent hair reduction is defined as long-term stable reduction in the number of hairs regrowing when measured at 6, 9 and 12 months after the completion of a treatment regime.It is indicated for the reduction of red pigmentation in hypertrophic and keloid scars where vascularity is an integral part of the scar.The laser is also indicated for pigmented lesions to reduce lesion size, for patients with lesions that would potentially benefit from aggressive treatment, and for patients with lesions that have not responded to other laser treatments.It is indicated for use on all skin types (Fitzpatrick I-VI ) including tanned skin, and the removal and permanent reduction of unwanted hair in Fitzpatrick I-VI, including suntanned skin types.

532 nm (Pulsed) Intended for the coagulation and hemostasis of vascular lesions. Dermatology/Plastic Surgery: For photocoagulation and hemostasis of vascular and cutaneous lesions in dermatology including but not limited to the following general categories:

– Vascular lesions [angiomas, hemangiomas (port wine), telangiectasia (facial or extremity telangiectasias, venous anomalies, leg veins

– Benign pigmented lesions (nevi, lentigines, chloasma, cafe au- lait, tattoos (red and green ink), verrucae, skin tags, keratoses, plaques, cutaneous lesion treatment (hemostasis, color lightening, blanching, flattening, reduction of lesion size).

755 nm (Pulsed) Indicated for stable long-term, or permanent hair reduction. Permanent hair reduction is defined as long-term stable reduction in the number of hairs regrowing when measured 6, 9, or 12 months after the completion of a treatment regime.

It is also indicated for the treatment of vascular lesions, benign pigmented lesions, and wrinkles.

It can be used for all skin types (Fitzpatrick I-VI) including tanned skin.

Optional Accessories
IPL 650-1200 nm
IPL 625-1200 nm
IPL 590-1200 nm
Indicated for permanent hair removal.
IPL 570-1200 nm
IPL 550-1200 nm
Indicated for photocoagulation of dermatological vascular lesion (i.e. face telangiectasia), photothermolysis of blood
vessels (treatment of facial and leg veins), and treatment of benign pigmented lesions.
IPL 400-1200 nm Indicated for inflammatory acne (acne vulgaris).
Nd:YAG 1320 nm (Pulsed)* Indicated for use in general surgery and dermatology for the incision, excision, ablation, vaporization, coagulation and
haemostasis of soft tissue. It is also indicated for the treatment of periorbital and perioral wrinkles, fine lines and wrinkles, and the treatment of back acne and atrophic acne scars.

*May not be available on all system configurations.

510(k) FDA Premarket Notification Number: K152012

THE EVO MDK SERIES combines the power and effectiveness of our EVO Q-Plus Series with our EVO Light Series devices, into one Premium Platform System:

Nd:YAG
(Q-Switched)
Nd:YAG
(Q-Switched)
Nd:YAG (Pulsed) Nd:YAG (Pulsed) Alexandrite Nd:YAG
Wavelength ¹ 1064 nm 532 nm 1064 532 755 1320
Pulse width 6 ns in QS mode
12 ns in OP mode
6 ns in QS mode
12 ns in OP mode
0.3-300 ms 2-25 ms 0.3-300 ms 5 – 10 ms
Max Energy 2000 mJ in PT mode
1500 mJ in OP mode
1000 mJ in QS mode
600 mJ in OP mode
500 mJ in QS mode
60J 3J 35J 10J
Max Fluence (J/cm²) 50 in PT mode
37 in OP mode
25 in QS mode
15 in OP mode
12.5 in QS mode
300 95 60  35
Repetition rate (Hz) up to 10 up to 10  up to 10  1 up to 10 up to 5
Burst Mode N/A N/A up to 3 pulses
tunable T-on & T-off times
N/A up to 3 pulses
tunable T-on & T-off times
N/A
Spot sizes (mm) ² 5×5, 4×4, 3×3
2×2 (optional)
5×5, 4×4, 3×3
2×2 (optional)
 2-5, 6, 8, 10, 12, 14, 16  2-5, 6  6, 8, 10, 12, 14, 16 6, 8, 10, 12
Beam Delivery Articulated Arm Articulated Arm Optical Fiber Optical Fiber Optical Fiber Optical Fiber
Cooling Options Optional stand-alone Zimmer Cryo 6 (purchased separately) Integrated Sapphire Tip
Electrical requirements 200-240 V; 3.7 kVA; 50-60 Hz
Comes standard with NEMA L630 plug.
Dimensions and Weight 21″(W)x41″(D)x42″(H)  |  330lbs.

 

¹ The wavelengths are pulsed individually and cannot be fired simultaneously.
² Spot sizes may vary by device configuration. Contact your Quanta representative for more information.

510(k) FDA Premarket Notification Number: K152012

 

  • This field is for validation purposes and should be left unchanged.

What can we help you with?  Quanta Aesthetic Lasers takes a consultative approach to sales and can help guide and educate you throughout your research and purchase processes.  We offer a full portfolio of high-end, European aesthetic devices, and our Sales Team is well-trained in both our technology and other lasers you may be looking at.  We will take the time to walk you through the benefits of your many options.

The Quanta team is available to you by phone, email, or through your submission of this Contact form.
Contact Us page group photo